Showing 11–20 of 105 results

Series 607,Dwyer, DIN Rail Mount Differential Pressure Transmitter

Series 607

LOW RANGE DIFFERENTIAL PRESSURE TRANSMITTER
±0.25% or ± 0.5% Full Scale Accuracy, Ranges from 0 to 0.1 in w.c.

FEATURES/BENEFITS
• High stability at low pressure ranges provides exceptional accuracy for ensuring
tight-control and minimizing costly out of specification conditions
• Provides sensitivity to pressure changes but resists vibration preventing drift and
less accurate readings
• Stainless steel housing meets standards for lab and clean room applications
APPLICATIONS
• Leak detection

• Clean room control

• Lab and fume hood pressure control

 

Series RSM,Dwyer, Room Status Monitor

Series RSM

ROOM STATUS MONITOR
For Sensing Low Pressure Using High Accuracy

FEATURES/BENEFITS
• Accurately monitor protective environments for negative or positive pressure
ensuring safety and reducing risk of catastrophic events
• Audible and visual alarm provides immediate local alerts allowing corrective action
to be taken quicker to eliminate the problem from becoming widespread
• Password protected set up menu helps to insure no errors by untrained personnel
• Optional BACnet communication from devices provides integration into building
control system for automated control and centralized monitoring and alarming
APPLICATIONS
• Hospital isolation wards

• Pharmaceutical

• Manufacturing
• Clean rooms

• Research labs

• Animal facilities

SERIES 605 | DWYER,MAGNEHELIC® DIFFERENTIAL PRESSURE

SERIES 605 | DWYER

MAGNEHELIC® DIFFERENTIAL PRESSURE
Indicating Transmitter

FEATURES/BENEFITS
• Easy to read gage permits viewing from far away
• Patented design provides quick response to pressure changes means no
delay in signaling and alerting to critical situations
• Durable and rugged housing and high-quality components combined provides
long-service life and minimized down-time
APPLICATIONS
• Monitor pressures in ducts, rooms, or total building pressures
• Filter monitoring
• Local indication of clean room pressures with process signal sent to control
room

SERIES DM-1000, DWYER,DIGIMAG®, DIGITAL DIFFERENTIAL PRESSURE AND FLOW GAGES

SERIES DM-1000 | DWYER

DIGIMAG® DIGITAL DIFFERENTIAL PRESSURE AND FLOW GAGES
24 Volt or Battery Powered, Fits in Magnehelic® Gage Cut-Out

FEATURES/BENEFITS
• Field programmed reduces installation time
• User selectable parameters for pressure, air velocity or flow permits same
device for multiple applications
• Specialized filter set point for alerts when maintenance is due
• Security levels permit matches the correct access to right skill
• Power versatility works with 9-24 VDC or 9 V battery allows deployment in a
variety of spaces wired or not
APPLICATIONS
• Filter monitoring
• Air velocity or flow
• Blower vacuum monitoring
• Fan pressure indication
• Duct, room or building pressures
• Clean room positive pressure indication

SERIES MS2 , DWYER,MAGNESENSE® II ,DIFFERENTIAL PRESSURE TRANSMITTER

SERIES MS2 | DWYER

MAGNESENSE® II DIFFERENTIAL PRESSURE TRANSMITTER
Monitors Pressure, Air Velocity & Air Flow, BACnet/Modbus® Communications

FEATURES/BENEFITS
• Field selectable ranges and output signal reduce inventory and the chances of
ordering an incorrect part
• BACnet or Modbus serial communications reduce wiring cost by daisy-chaining
the transmitters
• Our integral field-upgradeable display or plug-in remote display tool save
upfront material cost and allow for local viewing of measurements
APPLICATIONS
• Filter monitoring in air handler units
• Building pressure in pharmaceutical-semi-conductor clean rooms
• Duct static pressure in commercial buildings
• Air velocity/flow in VAV systems

SERIES 616W , DWYER,DIFFERENTIAL PRESSURE TRANSMITTER

SERIES 616W | DWYER

DIFFERENTIAL PRESSURE TRANSMITTER
NEMA 4X Enclosure, 0.25% FS Accuracy

FEATURES/BENEFITS
• NEMA 4X rated enclosure provides protection in harsh environments permitting
outdoor monitoring or in areas where dust and particulate matter exists
• Easy to read LCD display provides immediate local alerts allowing corrective
action to be taken quicker to eliminate the problem from becoming widespread
• Zero and span controls provides easy calibration checks and shorter installation
time to get device running and monitoring
APPLICATIONS
• Dust collection • Outdoor HVAC • Roof-top equipment

SERIES 616WL | DWYER,DIFFERENTIAL PRESSURE TRANSMITTER

SERIES 616WL | DWYER

DIFFERENTIAL PRESSURE TRANSMITTER
LOW RANGES DOWN TO 0.25 IN W.C. (60 PA), NEMA 4X HOUSING (IP66)

FEATURES/BENEFITS
• NEMA 4X rated enclosure provides protection in harsh environments permitting
outdoor monitoring or in areas where dust and particulate matter exists
• Easy to read LCD display provides immediate local alerts allowing corrective
action to be taken quicker to eliminate the problem from becoming widespread
• Zero and span controls provides easy calibration checks and shorter installation
time to get device running and monitoring
• High precision accuracy at low pressure ranges provides exceptional accuracy
for insuring tight-control and minimizing costly out of specification conditions
APPLICATIONS
• Low pressure applications

• Outdoor HVAC
• Dust collection

• Roof-top equipment

SERIES 647 , DWYER , WET/WET DIFFERENTIAL PRESSURE TRANSMITTER

SERIES 647 | DWYER

WET/WET DIFFERENTIAL PRESSURE TRANSMITTER
Ranges from 0 to 25 in w.c., ±1.0% Accuracy, NEMA 4 (IP56) Enclosure, 2-Wire

FEATURES/BENEFITS
• Versatile for liquid or gas supports designs requiring more precise
measure
ments in support of application
• Temperature compensated improves performance of device for accurate
measure
ment under different operating environments.
• Output signal provides capability to interface with automation systems to
centralize
monitoring
APPLICATIONS
• Flow

• HVAC automation
• Process control

• Pneumatic systems

SERIES 645 , DWYER , WET/WET DIFFERENTIAL PRESSURE TRANSMITTER

SERIES 645 | DWYER

WET/WET DIFFERENTIAL PRESSURE TRANSMITTER
±0.25% Accuracy, Quick Response, 2-Wire Design

FEATURES/BENEFITS
• Versatile, high-accuracy device for liquid or gas supports designs requiring
more precise measurements in support
of application
• Optional 3-way valve manifold supports simplifying installation or removal of
transmitter without interrupting process
APPLICATIONS
• Process control

• Filter monitoring
• Refrigeration equipment

• Pump speed control
• HVAC equipment

• Liquid level measurement2

SERIES 629 , DWYER ,WET/WET DIFFERENTIAL PRESSURE TRANSMITTER

SERIES 629 | DWYER

WET/WET DIFFERENTIAL PRESSURE TRANSMITTER
0.5% Accuracy, NEMA 4X (IP66) Enclosure

FEATURES/BENEFITS
• Versatile, high-accuracy device for liquid or gas supports designs requiring
more precise measurements in support
of application
• Minimum components provide excellent response and reliability
• Span and zero controls reduce installation and service time
• Terminal block reduces wiring difficulties saving installation time
• Optional LED indicator provides local status to identify operational conditions.
• Optional 3-way valve manifold supports higher line pressures or simplifying
removal of transmitter without interruptin
g process
APPLICATIONS
• Flow elements

• Heat exchangers

• Filters
• Coils

• Chiller

• Pumps