RDG100 Room thermostat, AC 230 V, for fan coil units and universal applications

RDG100 Room thermostat, AC 230 V, for fan coil units and universal applications

T· RDG100..: Operating voltage AC 230 V, On/Off, 3-positon or PWM control
outputs
· RDG110: Operating voltage AC 230 V, On/Off relay (SPDT) outputs
· RDG110U: Operating voltage AC/DC 24 V, On/Off relay (SPDT) outputs
· RDG100../RDG110..: Output for 1-speed and 3-speed
· RDG160T..: Operating voltage AC/DC 24 V, DC 0…10 V or On/Off control
outputs
· RDG160T..: Output for 1-speed, 3-speed or ECM fan DC 0…10 V
· Operating modes: Comfort, Economy and Protection
· Automatic or manual fan speed
· 3 multifunctional inputs for keycard contact, external sensor, etc
· Automatic or manual heating/cooling changeover
· Adjustable commissioning and control parameters
· Minimum and maximum setpoint limitation
· Backlit display
Additional features of RDG100T, RDG160T.., RDG100T/H:
· Infrared remote control receiver
· Auto Timer mode with 8 programmable timers
· Auto timer can be disabled via P02
· Auto timer can be disabled via DIP switches (RDG160T..)
· Landscape design (RDG100T/H only)
· Selectable relay output functions (RDG160T..)

RDG110 Room thermostat, AC 230 V, for fan coil units and heat pump applications

RDG110 Room thermostat, AC 230 V, for fan coil units and heat pump applications

T· RDG100..: Operating voltage AC 230 V, On/Off, 3-positon or PWM control
outputs
· RDG110: Operating voltage AC 230 V, On/Off relay (SPDT) outputs
· RDG110U: Operating voltage AC/DC 24 V, On/Off relay (SPDT) outputs
· RDG100../RDG110..: Output for 1-speed and 3-speed
· RDG160T..: Operating voltage AC/DC 24 V, DC 0…10 V or On/Off control
outputs
· RDG160T..: Output for 1-speed, 3-speed or ECM fan DC 0…10 V
· Operating modes: Comfort, Economy and Protection
· Automatic or manual fan speed
· 3 multifunctional inputs for keycard contact, external sensor, etc
· Automatic or manual heating/cooling changeover
· Adjustable commissioning and control parameters
· Minimum and maximum setpoint limitation
· Backlit display
Additional features of RDG100T, RDG160T.., RDG100T/H:
· Infrared remote control receiver
· Auto Timer mode with 8 programmable timers
· Auto timer can be disabled via P02
· Auto timer can be disabled via DIP switches (RDG160T..)
· Landscape design (RDG100T/H only)
· Selectable relay output functions (RDG160T..)

RDF110 Room thermostat for 2-pipe fan coils or DX-type equipment, return air temperature sensor

RDF110 Room thermostat for 2-pipe fan coils or DX-type equipment, return air temperature sensor

Output for on / off valve actuator or 1-stage compressor
3-speed fan control: Automatic or manual
Adjustable commissioning and control parameters
Optional display of room temperature or setpoint
Minimum and maximum setpoint limitation
Operating voltage AC 230 V
Additional features of RDF110
Automatic heating / cooling changeover
Operating modes: Normal operation, Economy (Energy saving) and Protection (Standby)
Input for heating / cooling changeover or return air temperature sensor
Potential-free input for operating mode changeover (key card contact, etc.)
Function for avoiding damage resulting from moisture
Additional features of RDF110.2
Manual heating / cooling changeover
Operating modes: Normal operation, Protection (Standby)
Optional
Infrared remote control (RDF110/IR, RDF110.2/IR)

RDF110.2 Room thermostat for 2-pipe fan coils or DX-type equipment

RDF110.2 Room thermostat for 2-pipe fan coils or DX-type equipment

Output for on / off valve actuator or 1-stage compressor
3-speed fan control: Automatic or manual
Adjustable commissioning and control parameters
Optional display of room temperature or setpoint
Minimum and maximum setpoint limitation
Operating voltage AC 230 V
Additional features of RDF110
Automatic heating / cooling changeover
Operating modes: Normal operation, Economy (Energy saving) and Protection (Standby)
Input for heating / cooling changeover or return air temperature sensor
Potential-free input for operating mode changeover (key card contact, etc.)
Function for avoiding damage resulting from moisture
Additional features of RDF110.2
Manual heating / cooling changeover
Operating modes: Normal operation, Protection (Standby)
Optional
Infrared remote control (RDF110/IR, RDF110.2/IR)

RDG100T Room thermostat, AC 230 V, for fan coil units and universal applications, 7-day time switch, vertical

RDG100T Room thermostat, AC 230 V, for fan coil units and universal applications, 7-day time switch, vertical

· RDG100..: Operating voltage AC 230 V, On/Off, 3-positon or PWM control
outputs
· RDG110: Operating voltage AC 230 V, On/Off relay (SPDT) outputs
· RDG110U: Operating voltage AC/DC 24 V, On/Off relay (SPDT) outputs
· RDG100../RDG110..: Output for 1-speed and 3-speed
· RDG160T..: Operating voltage AC/DC 24 V, DC 0…10 V or On/Off control
outputs
· RDG160T..: Output for 1-speed, 3-speed or ECM fan DC 0…10 V
· Operating modes: Comfort, Economy and Protection
· Automatic or manual fan speed
· 3 multifunctional inputs for keycard contact, external sensor, etc
· Automatic or manual heating/cooling changeover
· Adjustable commissioning and control parameters
· Minimum and maximum setpoint limitation
· Backlit display
Additional features of RDG100T, RDG160T.., RDG100T/H:
· Infrared remote control receiver
· Auto Timer mode with 8 programmable timers
· Auto timer can be disabled via P02
· Auto timer can be disabled via DIP switches (RDG160T..)
· Landscape design (RDG100T/H only)
· Selectable relay output functions (RDG160T..)

RDG100T/H Room thermostat, AC 230 V, for fan coil units and universal applications, 7-day time switch, horizontal

RDG100T/H Room thermostat, AC 230 V, for fan coil units and universal applications, 7-day time switch, horizontal

· RDG100..: Operating voltage AC 230 V, On/Off, 3-positon or PWM control
outputs
· RDG110: Operating voltage AC 230 V, On/Off relay (SPDT) outputs
· RDG110U: Operating voltage AC/DC 24 V, On/Off relay (SPDT) outputs
· RDG100../RDG110..: Output for 1-speed and 3-speed
· RDG160T..: Operating voltage AC/DC 24 V, DC 0…10 V or On/Off control
outputs
· RDG160T..: Output for 1-speed, 3-speed or ECM fan DC 0…10 V
· Operating modes: Comfort, Economy and Protection
· Automatic or manual fan speed
· 3 multifunctional inputs for keycard contact, external sensor, etc
· Automatic or manual heating/cooling changeover
· Adjustable commissioning and control parameters
· Minimum and maximum setpoint limitation
· Backlit display
Additional features of RDG100T, RDG160T.., RDG100T/H:
· Infrared remote control receiver
· Auto Timer mode with 8 programmable timers
· Auto timer can be disabled via P02
· Auto timer can be disabled via DIP switches (RDG160T..)
· Landscape design (RDG100T/H only)
· Selectable relay output functions (RDG160T..)

RDF300 Flush-mount room thermostat for rectangular conduit box, for 2-/4-pipe fan coils or DX type equipmen

RDF300 Flush-mount room thermostat for rectangular conduit box, for 2-/4-pipe fan coils or DX type equipmen

· RDF300 / RDF400 / RDF600/RDF600T:
AC 230 V operating voltage, on/off or 3-position control outputs
· RDF340…:AC 24 V, operating voltage, DC 0…10 V control outputs
· Output for 3-speed or 1-speed fan
· 2 multifunctional inputs for keycard contact, external sensor, etc.
· Operating modes: Comfort, Economy and Protection
· Automatic or manual fan speed control
· Automatic or manual heating/cooling changeover
· Adjustable commissioning and control parameters
· Minimum and maximum setpoint limitation
· User and parameter settings can be retained or restored with power loss
Additional features
· Backlit LCD (RDF300.02, RDF400.01, RDF600, RDF600T)
· Infrared remote control receiver (RDF400.01, RDF600T)
· Auto Timer mode with 8 programmable timers (RDF400.01, RDF600T)
Type of mounting / suitable conduit boxes
· RDF600… for round CEE box, with min 60 mm diameter, min 40 mm depth
· RDF3… / RDF400… for recessed square box with 60.3 mm fixing centers

RDF300.02 Flush-mount room thermostat for rectangular conduit box, for 2-/4-pipe fan coils or DX type equipment, backlit LCD

RDF300.02 Flush-mount room thermostat for rectangular conduit box, for 2-/4-pipe fan coils or DX type equipment, backlit LCD

· RDF300 / RDF400 / RDF600/RDF600T:
AC 230 V operating voltage, on/off or 3-position control outputs
· RDF340…:AC 24 V, operating voltage, DC 0…10 V control outputs
· Output for 3-speed or 1-speed fan
· 2 multifunctional inputs for keycard contact, external sensor, etc.
· Operating modes: Comfort, Economy and Protection
· Automatic or manual fan speed control
· Automatic or manual heating/cooling changeover
· Adjustable commissioning and control parameters
· Minimum and maximum setpoint limitation
· User and parameter settings can be retained or restored with power loss
Additional features
· Backlit LCD (RDF300.02, RDF400.01, RDF600, RDF600T)
· Infrared remote control receiver (RDF400.01, RDF600T)
· Auto Timer mode with 8 programmable timers (RDF400.01, RDF600T)
Type of mounting / suitable conduit boxes
· RDF600… for round CEE box, with min 60 mm diameter, min 40 mm depth
· RDF3… / RDF400… for recessed square box with 60.3 mm fixing centers