Siemens Semi flush-mount room thermostats RDE410/EH Siemens Semi flush-mount room thermostats RDE410/EH Key features of both types of thermostats: ∂ Operating voltage AC 230 V ∂ 2-position control with On/Off control output ∂ Maximum load 16 A ∂ Protection class IP31, suitable for installation in wet rooms ∂ Input for cable temperature sensor NTC 3 k (QAP1030/UFH) for the floor (note: cable temperature sensor must be ordered separately) ∂ Floor temperature limitation with cable temperature sensor ∂ Operating modes: Comfort, Economy and Frost Protection ∂ Minimum and maximum limitation of setpoint setting range ∂ Backlit white LCD ∂ Suitable for use with standard conduit boxes in Europe (CEE/VDE) and Asia-Pacific (min. depth 40 mm) อ่านเพิ่ม
Siemens Semi flush-mount room thermostats RDD310/EH Siemens Semi flush-mount room thermostats RDD310/EH Key features of both types of thermostats: ∂ Operating voltage AC 230 V ∂ 2-position control with On/Off control output ∂ Maximum load 16 A ∂ Protection class IP31, suitable for installation in wet rooms ∂ Input for cable temperature sensor NTC 3 k (QAP1030/UFH) for the floor (note: cable temperature sensor must be ordered separately) ∂ Floor temperature limitation with cable temperature sensor ∂ Operating modes: Comfort, Economy and Frost Protection ∂ Minimum and maximum limitation of setpoint setting range ∂ Backlit white LCD ∂ Suitable for use with standard conduit boxes in Europe (CEE/VDE) and Asia-Pacific (min. depth 40 mm) อ่านเพิ่ม
Siemens Wireless room thermostat RDH100RF/SET with LCD Siemens Wireless room thermostat RDH100RF/SET with LCD Large LCD display ● RDH100RF, transmitter, battery powered ● RCR100/433, receiver, mains powered ● Communication of the set is bonded ex factory ● TPI control for use with ON/OFF heating systems อ่านเพิ่ม
Siemens Room thermostat RDH100/SPL with set point limitation Siemens Room thermostat RDH100/SPL with set point limitation Large LCD ● Battery-powered: 2 x alkaline batteries type AA, 1.5 v ● TPI control for use with ON/OFF heating systems อ่านเพิ่ม
Siemens RDF302 Flush-mounted room thermostats with RS485 Modbus communications Siemens RDF302 Flush-mounted room thermostats with RS485 Modbus communications RS485 communicative interface in Modbus RTU slave mode ∂ Backlit display ∂ 2P / PI / P control ∂ Outputs for on/off or 3-position control ∂ Outputs for 3-speed or 1-speed fan ∂ 2 multifunctional inputs for keycard contact, external sensor, etc. ∂ Operating modes: Comfort, Economy and Protection ∂ Automatic or manual fan speed control ∂ Automatic or manual heating/cooling changeover ∂ Minimum and maximum limitation of room temperature setpoint ∂ Control depending on the room or the return air temperature ∂ Adjustable commissioning and control parameters via local HMI or RS485 Modbus ∂ Mounting on recessed square conduit box, 60.3 mm fixing centers ∂ AC 230 V operating voltage ∂ User and parameter settings can be retained or restored with power loss อ่านเพิ่ม
Siemens RDG405KN Room thermostats with KNX communications Siemens RDG405KN Room thermostats with KNX communications KNX communications Output DC 0…10 V for VAV actuator and auxiliary output ON/OFF, PWM or 3-position or 3-position for VAV actuator and auxiliary output DC 0…10 V 2 multifunctional inputs for keycard contact, external room / return air temperature (1x, QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector 1 input DC 0…10 V for damper position feedback, for CO2 sensor Operating modes: Comfort, Economy and Protection Modulating PI control Control depending on the room or the return air temperature and air quality Automatic or manual heating / cooling changeover Adjustable commissioning and control parameters Minimum and maximum setpoint limitation Minimum and maximum limitation of air flow signal Output signal inversion (DC 0…10 V) as an option Backlit display อ่านเพิ่ม
Siemens RDG400KN Room thermostats with KNX communications Siemens RDG400KN Room thermostats with KNX communications ∂ KNX bus communications (S- and LTE-Mode) ∂ Backlit display ∂ PI/P control ∂ Output for VAV box/air damper: DC 0…10 V/3-position/KNX LTE-Mode ∂ Output for heating/cooling coil: On/Off, PWM or 3-position/DC 0…10 V ∂ Output signal inversion as an option (DC 0…10 V ⇓ DC 10…0 V) ∂ 2 multifunctional inputs for keycard contact, external sensor, etc. ∂ 1 DC 0…10 V input for external sensor or feedback of air damper position ∂ Operating modes: Comfort, Economy and Protection ∂ Control depending on room or return air temperature ∂ Optimized operation of supply air fan: Input DC 0…10 V for feedback of air damper position ∂ Automatic or manual heating/cooling changeover ∂ Minimum and maximum limitation of room temperature setpoint ∂ Minimum and maximum limitation of air flow signal ∂ Adjustable commissioning and control parameters ∂ Commissioning with Synco ACS790, ETS or via local HMI ∂ Integration into Synco; integration into Desigo via group addressing (ETS) or individual addressing ∂ Integration into third-party system via group addressing (ETS) ∂ Indoor air quality (IAQ) control loop with external CO2 sensor (DC 0…10 V or KNX LTE- and S-Mode) (RDG405KN) ∂ Operating voltage AC 24 V ∂ Interworking with KNX CO2/temperature sensors (LTE- and S-Mode) อ่านเพิ่ม
Siemens RDU340 Flush-mounted room thermostat Siemens RDU340 Flush-mounted room thermostat Output for a DC 0…10 V actuator and AC 230V electrical heater (ON-OFF) 2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact Operating modes: Comfort, Energy Saving and Protection Modulating PI control Control depending on the room or the return air temperature Automatic or manual heating/cooling changeover Adjustable commissioning and control parameters Minimum and maximum setpoint limitation Adjustable minimum and maximum limitation for air flow signal DC 0…10V Output signal inversion as an option Mounting on recessed rectangular conduit box, 60.3 mm fixing centers อ่านเพิ่ม
Siemens RDG400 Wall-mounted room thermostat with LCD for VAV heating and cooling systems Siemens RDG400 Wall-mounted room thermostat with LCD for VAV heating and cooling systems Modulating PI control ∂ Control depending on the room or the return air temperature ∂ Output for DC 0…10 V actuator and auxiliary output On/Off, PWM or 3-position ∂ Automatic or manual heating/cooling changeover ∂ Operating modes: Comfort, Economy and Protection ∂ 3 multifunctional inputs for keycard contact, external sensor, etc. ∂ Adjustable commissioning and control parameters ∂ Minimum and maximum setpoint limitation ∂ Minimum and maximum limitation of air flow signal DC 0…10 V ∂ Output signal inversion as an option ∂ Operating voltage AC 24 V ∂ Backlit display อ่านเพิ่ม
Siemens RDF530 Flush mount room thermostat for 4-pipe fan coils Siemens RDF530 Flush mount room thermostat for 4-pipe fan coils LED backlit display ● Keylock function ● Display either room temperature or setpoint ● Comfort and Protection(Off) operating modes ● Automatic or manual heating/cooling changeover ● Automatic or manual 3-speed fan control ● Selectable fan operation in deadzone ● Timer with delay Off function: preset or user selection from 1 to 23 hours ● Minimum and maximum setpoint limitation ● Return to previous operating mode or Protection(Off) upon power down ● Internal sensor calibration ● Adjustable commissioning and control parameters ● Fit into 86×86 conduit boxes ● Housing available in different colors อ่านเพิ่ม
Siemens RDF510 Flush-mount room thermostat for 2-pipe fan coils Siemens RDF510 Flush-mount room thermostat for 2-pipe fan coils LED backlit display ● Keylock function ● Display either room temperature or setpoint ● Comfort and Protection(Off) operating modes ● Automatic or manual heating/cooling changeover ● Automatic or manual 3-speed fan control ● Selectable fan operation in deadzone ● Timer with delay Off function: preset or user selection from 1 to 23 hours ● Minimum and maximum setpoint limitation ● Return to previous operating mode or Protection(Off) upon power down ● Internal sensor calibration ● Adjustable commissioning and control parameters ● Fit into 86×86 conduit boxes ● Housing available in different colors อ่านเพิ่ม
QFA3280.EWSC Room Temp Sensor, RH 2%, for TEC, Digital signal, Temp Sensing, Tool Port QFA3280.EWSC Room Temp Sensor, RH 2%, for TEC, Digital signal, Temp Sensing, Tool Port Operating voltage AC 24 V / DC 13.5…35 V • Signal output DC 0…10 V / 4…20 mA for relative humidity and temperature • Very high measuring accuracy across the entire measuring range • Capacitive humidity measurement • Recalibration service • Test function for loop test • Range of use −40…+70 °C / 0…100 % r. h. with LCD display −25…+70 °C / 0…100 % r. h. อ่านเพิ่ม
QFA4160D Room sensor for humidity (DC 0..10V) and temperature (DC 0..10V) with calibration certificate, with display QFA4160D Room sensor for humidity (DC 0..10V) and temperature (DC 0..10V) with calibration certificate, with display Operating voltage AC 24 V / DC 13.5…35 V • Signal output DC 0…10 V / 4…20 mA for relative humidity and temperature • Very high measuring accuracy across the entire measuring range • Capacitive humidity measurement • Recalibration service • Test function for loop test • Range of use −40…+70 °C / 0…100 % r. h. with LCD display −25…+70 °C / 0…100 % r. h. อ่านเพิ่ม
QFA4160 Room sensor for humidity (DC 0..10V) and temperature (DC 0..10V) with calibration certificate QFA4160 Room sensor for humidity (DC 0..10V) and temperature (DC 0..10V) with calibration certificate Operating voltage AC 24 V / DC 13.5…35 V • Signal output DC 0…10 V / 4…20 mA for relative humidity and temperature • Very high measuring accuracy across the entire measuring range • Capacitive humidity measurement • Recalibration service • Test function for loop test • Range of use −40…+70 °C / 0…100 % r. h. with LCD display −25…+70 °C / 0…100 % r. h. อ่านเพิ่ม
QFA3171D Room sensor for humidity (4…20 mA) and temperature (4…20 mA) for demanding requirements, with display QFA3171D Room sensor for humidity (4…20 mA) and temperature (4…20 mA) for demanding requirements, with display • Operating voltage AC 24 V / DC 13.5…35 V • Signal output DC 0…10 V / 4…20 mA for relative humidity and temperature • Very high measuring accuracy across the entire measuring range • Capacitive humidity measurement • Function test • Range of use −40…+70 °C / 0…100 % r. h. with LCD display −25…+70 °C / 0…100 % r. h. Use อ่านเพิ่ม
QFA3171 Room sensor for humidity (4…20 mA) and temperature (4…20 mA) for demanding requirements QFA3171 Room sensor for humidity (4…20 mA) and temperature (4…20 mA) for demanding requirements • Operating voltage AC 24 V / DC 13.5…35 V • Signal output DC 0…10 V / 4…20 mA for relative humidity and temperature • Very high measuring accuracy across the entire measuring range • Capacitive humidity measurement • Function test • Range of use −40…+70 °C / 0…100 % r. h. with LCD display −25…+70 °C / 0…100 % r. h. Use อ่านเพิ่ม