HR2 Room humidistat, 1- or 2-step HR2 room-humidistat-1-or-2-step One or two steps • Protection class IP21 (can be used in bathrooms) • Changeover contact 250V AC 5A (HR1-DH: 10A) HR1 and HR2 is a series of electro-mechanical room humidistats for controlling humidifying and/or dehumidifying in HVAC systems. • High level of reliability • Settings can be locked อ่านเพิ่ม
HR1-DH Room humidistat, 1- or 2-step HR1-DH-room-humidistat-1-or-2-step One or two steps • Protection class IP21 (can be used in bathrooms) • Changeover contact 250V AC 5A (HR1-DH: 10A) HR1 and HR2 is a series of electro-mechanical room humidistats for controlling humidifying and/or dehumidifying in HVAC systems. • High level of reliability • Settings can be locked อ่านเพิ่ม
HR1 Room humidistat, 1- or 2-step HR1 Room humidistat, 1- or 2-step One or two steps • Protection class IP21 (can be used in bathrooms) • Changeover contact 250V AC 5A (HR1-DH: 10A) HR1 and HR2 is a series of electro-mechanical room humidistats for controlling humidifying and/or dehumidifying in HVAC systems. • High level of reliability • Settings can be locked อ่านเพิ่ม
HR-S Room humidistat HR-S Room humidistat 1-step Protection class IP30 Changeover contact 250 V AC, 5 A High reliability and accuracy Setpoint settings can be locked อ่านเพิ่ม
FLS304XT Liquid flow switch FLS304XT Liquid flow switch Fits pipe sizes ranging from 1” to 8” • Available for use in seawater or corrosive media • Adjustable or fixed hysteresis FLS is a series of electro-mechanical flow switches for use in heating and cooling systems. • Breaking capacity 15 A at 230 V AC • Protection class IP65 • Models with TÜV approval available อ่านเพิ่ม
FLS304X Liquid flow switch FLS304X Liquid flow switch Fits pipe sizes ranging from 1” to 8” • Available for use in seawater or corrosive media • Adjustable or fixed hysteresis FLS is a series of electro-mechanical flow switches for use in heating and cooling systems. • Breaking capacity 15 A at 230 V AC • Protection class IP65 • Models with TÜV approval available อ่านเพิ่ม
AFS1 Air flow switch AFS1 Air flow switch Short facts about AFS1 • Paddle can be trimmed to fit higher air flows • For vertical or horizontal mounting • Breaking capacity 15 (8) A at 24…250 V AC • Protection class IP65 อ่านเพิ่ม
AVDT25N Air velocity transmitter AVDT25N Air velocity transmitter Selectable working range 0…10/15/20 m/s 99 Output signal 0…10 V DC or 4…20 mA 99 Supply voltage 24 V AC/DC 99 Adjustable damping time 99 Shor t reaction time 99 Adjustable probe inser tion length อ่านเพิ่ม
CTHRC2(-D) CO2, humidity and temperature transmitters with communication CTHRC2(-D) CO2, humidity and temperature transmitters with communication Short facts about CTHRC2(-D) • Output signal Modbus • CO2 concentration, 0…2000 ppm • Temperature, 0…50°C • Humidity, 10…90 % RH • Good long-term stability • Modbus communication อ่านเพิ่ม
CTRC2(-D) CO2 and temperature transmitters for Modbus communication CTRC2(-D) CO2 and temperature transmitters for Modbus communication Short facts about CTRC2(-D) • Output signal Modbus • CO2 concentration, 0…2000 ppm • Temperature, 0…50°C • Good long-term stability • Modbus communication อ่านเพิ่ม
CTHR2A(-D) CO2, humidity and temperature transmitters CTHR2A(-D) CO2, humidity and temperature transmitters Short facts about CTHR2A(-D) • Output signal CO2, 0…10 V DC referring to 0…2000 ppm • Output signal temperature, 0…10 V DC referring to 0…50°C • Output signal humidity, 0…10 V DC referring to 0…100 % RH • CO2 concentration, 0…2000 ppm • Temperature, 0…50°C • Humidity, 10…90 % RH • Good long-term stability อ่านเพิ่ม
CTHR2(-D) CO2, humidity and temperature transmitters CTHR2(-D) CO2, humidity and temperature transmitters Output signal CO2, 0…10 V DC referring to 0…2000 ppm 99 Temperature sensor, PT1000 class DIN B 99 Output signal humidity, 0…10 V DC referring to 0…100 % RH 99 CO2 concentration, 0…2000 ppm 99 Temperature, 0…50°C, PT1000 99 Humidity, 10…90 % RH 99 Good long-term stability อ่านเพิ่ม
CTRT2A(-D) CO2 and temperature transmitters CTRT2A(-D) CO2 and temperature transmitters Output signal CO2, 0…10 V DC referring to 0…2000 ppm 99 Temperature sensors 0…10 V DC referring to 0…50°C and PT1000 class DIN B 99 CO2 concentration, 0…2000 ppm 99 Temperature 0…50°C 99 Good long-term stability อ่านเพิ่ม
CO2RT-R(-D) CO2-sensors with built-in relay CO2RT-R(-D) CO2-sensors with built-in relay Built-in relay • CO2-level 0…2000 ppm • Excellent long term stability CO2RT-R and CO2RT-R-D are room sensors for measuring carbon dioxide levels in air. They have a builtin relay with switching output. • Snap-in cover • Model with display (CO2RT-R-D) อ่านเพิ่ม
CTDT2 CO2 and temperature transmitter for duct mounting CTDT2 CO2 and temperature transmitter for duct mounting Short facts about CTDT2 • Combined CO2 and temperature transmitter • Infrared technology (NDIR) • CO2 concentration 0…2000 ppm measuring range • Excellent long-term stability • Easy installation and service-friendly housing • Probe only 12 mm • Automatic CO2 calibration อ่านเพิ่ม
CO2DT-R CO2-transmitter for duct mounting CO2DT-R CO2-transmitter for duct mounting Short facts about CO2DT-R • Infrared technology (NDIR) • CO2 concentration 0…2000 ppm measuring range • Excellent long-term stability • Easy installation and service-friendly housing • Probe only 12 mm • Automatic CO2 calibration อ่านเพิ่ม